[{"volume":13,"file_date_updated":"2023-11-25T11:05:37Z","title":"Washing and Abrasion Resistance of Textile Electrodes for ECG Measurements","date_created":"2023-11-25T11:06:05Z","funded_apc":"1","quality_controlled":"1","publication":"Coatings","user_id":"220548","type":"journal_article","publication_identifier":{"eissn":["2079-6412"]},"file":[{"success":1,"date_updated":"2023-11-25T11:05:37Z","date_created":"2023-11-25T11:05:37Z","creator":"aehrmann","file_size":3807733,"file_name":"_2023_Doci_Coatings13_1624.pdf","content_type":"application/pdf","relation":"main_file","file_id":"3754","access_level":"open_access"}],"intvolume":"        13","doi":"10.3390/coatings13091624","status":"public","article_number":"1624","year":"2023","article_type":"original","publication_status":"published","issue":"9","urn":"urn:nbn:de:hbz:bi10-37530","keyword":["electrocardiogram (ECG)","textile electrodes","conductive coating","conductive yarn","sensor","Arduino"],"main_file_link":[{"open_access":"1","url":"https://www.mdpi.com/2079-6412/13/9/1624"}],"oa":"1","tmp":{"short":"CC BY (4.0)","legal_code_url":"https://creativecommons.org/licenses/by/4.0/legalcode","name":"Creative Commons Attribution 4.0 International Public License (CC-BY 4.0)","image":"/images/cc_by.png"},"has_accepted_license":"1","publisher":"MDPI AG","date_updated":"2026-03-17T15:28:49Z","citation":{"alphadin":"<span style=\"font-variant:small-caps;\">Doci, Dajana</span> ; <span style=\"font-variant:small-caps;\">Ademi, Melisa</span> ; <span style=\"font-variant:small-caps;\">Tuvshinbayar, Khorolsuren</span> ; <span style=\"font-variant:small-caps;\">Richter, Niclas</span> ; <span style=\"font-variant:small-caps;\">Ehrmann, Guido</span> ; <span style=\"font-variant:small-caps;\">Spahiu, Tatjana</span> ; <span style=\"font-variant:small-caps;\">Ehrmann, Andrea</span>: Washing and Abrasion Resistance of Textile Electrodes for ECG Measurements. In: <i>Coatings</i> Bd. 13, MDPI AG (2023), Nr. 9","apa":"Doci, D., Ademi, M., Tuvshinbayar, K., Richter, N., Ehrmann, G., Spahiu, T., &#38; Ehrmann, A. (2023). Washing and Abrasion Resistance of Textile Electrodes for ECG Measurements. <i>Coatings</i>, <i>13</i>(9). <a href=\"https://doi.org/10.3390/coatings13091624\">https://doi.org/10.3390/coatings13091624</a>","bibtex":"@article{Doci_Ademi_Tuvshinbayar_Richter_Ehrmann_Spahiu_Ehrmann_2023, title={Washing and Abrasion Resistance of Textile Electrodes for ECG Measurements}, volume={13}, DOI={<a href=\"https://doi.org/10.3390/coatings13091624\">10.3390/coatings13091624</a>}, number={91624}, journal={Coatings}, publisher={MDPI AG}, author={Doci, Dajana and Ademi, Melisa and Tuvshinbayar, Khorolsuren and Richter, Niclas and Ehrmann, Guido and Spahiu, Tatjana and Ehrmann, Andrea}, year={2023} }","ieee":"D. Doci <i>et al.</i>, “Washing and Abrasion Resistance of Textile Electrodes for ECG Measurements,” <i>Coatings</i>, vol. 13, no. 9, 2023.","mla":"Doci, Dajana, et al. “Washing and Abrasion Resistance of Textile Electrodes for ECG Measurements.” <i>Coatings</i>, vol. 13, no. 9, 1624, MDPI AG, 2023, doi:<a href=\"https://doi.org/10.3390/coatings13091624\">10.3390/coatings13091624</a>.","ama":"Doci D, Ademi M, Tuvshinbayar K, et al. Washing and Abrasion Resistance of Textile Electrodes for ECG Measurements. <i>Coatings</i>. 2023;13(9). doi:<a href=\"https://doi.org/10.3390/coatings13091624\">10.3390/coatings13091624</a>","short":"D. Doci, M. Ademi, K. Tuvshinbayar, N. Richter, G. Ehrmann, T. Spahiu, A. Ehrmann, Coatings 13 (2023).","chicago":"Doci, Dajana, Melisa Ademi, Khorolsuren Tuvshinbayar, Niclas Richter, Guido Ehrmann, Tatjana Spahiu, and Andrea Ehrmann. “Washing and Abrasion Resistance of Textile Electrodes for ECG Measurements.” <i>Coatings</i> 13, no. 9 (2023). <a href=\"https://doi.org/10.3390/coatings13091624\">https://doi.org/10.3390/coatings13091624</a>."},"author":[{"first_name":"Dajana","full_name":"Doci, Dajana","last_name":"Doci"},{"full_name":"Ademi, Melisa","last_name":"Ademi","first_name":"Melisa"},{"first_name":"Khorolsuren","id":"222971","orcid":"0009-0001-7114-1842","full_name":"Tuvshinbayar, Khorolsuren","last_name":"Tuvshinbayar"},{"first_name":"Niclas","id":"224900","last_name":"Richter","orcid":"0000-0002-8980-0957","full_name":"Richter, Niclas"},{"first_name":"Guido","full_name":"Ehrmann, Guido","last_name":"Ehrmann"},{"first_name":"Tatjana","full_name":"Spahiu, Tatjana","last_name":"Spahiu"},{"last_name":"Ehrmann","full_name":"Ehrmann, Andrea","orcid":"0000-0003-0695-3905","id":"223776","first_name":"Andrea"}],"language":[{"iso":"eng"}],"_id":"3753"},{"main_file_link":[{"open_access":"1","url":"https://www.mdpi.com/2673-7248/2/2/14"}],"alternative_id":["2653","2647"],"oa":"1","tmp":{"short":"CC BY (4.0)","legal_code_url":"https://creativecommons.org/licenses/by/4.0/legalcode","name":"Creative Commons Attribution 4.0 International Public License (CC-BY 4.0)","image":"/images/cc_by.png"},"has_accepted_license":"1","urn":"urn:nbn:de:hbz:bi10-20230","keyword":["electrocardiogram (ECG)","Arduino","electrodes","conductive coating","conductive yarn","sensor"],"issue":"2","publication_status":"published","article_type":"original","language":[{"iso":"eng"}],"_id":"2023","author":[{"full_name":"Tuvshinbayar, Khorolsuren","orcid":"0009-0001-7114-1842","last_name":"Tuvshinbayar","id":"222971","first_name":"Khorolsuren"},{"first_name":"Guido","last_name":"Ehrmann","full_name":"Ehrmann, Guido"},{"last_name":"Ehrmann","orcid":"0000-0003-0695-3905","full_name":"Ehrmann, Andrea","first_name":"Andrea","id":"223776"}],"citation":{"ama":"Tuvshinbayar K, Ehrmann G, Ehrmann A. 50/60 Hz Power Grid Noise as a Skin Contact Measure of Textile ECG Electrodes. <i>Textiles</i>. 2022;2(2):265-274. doi:<a href=\"https://doi.org/10.3390/textiles2020014\">10.3390/textiles2020014</a>","mla":"Tuvshinbayar, Khorolsuren, et al. “50/60 Hz Power Grid Noise as a Skin Contact Measure of Textile ECG Electrodes.” <i>Textiles</i>, vol. 2, no. 2, MDPI AG, 2022, pp. 265–74, doi:<a href=\"https://doi.org/10.3390/textiles2020014\">10.3390/textiles2020014</a>.","chicago":"Tuvshinbayar, Khorolsuren, Guido Ehrmann, and Andrea Ehrmann. “50/60 Hz Power Grid Noise as a Skin Contact Measure of Textile ECG Electrodes.” <i>Textiles</i> 2, no. 2 (2022): 265–74. <a href=\"https://doi.org/10.3390/textiles2020014\">https://doi.org/10.3390/textiles2020014</a>.","short":"K. Tuvshinbayar, G. Ehrmann, A. Ehrmann, Textiles 2 (2022) 265–274.","bibtex":"@article{Tuvshinbayar_Ehrmann_Ehrmann_2022, title={50/60 Hz Power Grid Noise as a Skin Contact Measure of Textile ECG Electrodes}, volume={2}, DOI={<a href=\"https://doi.org/10.3390/textiles2020014\">10.3390/textiles2020014</a>}, number={2}, journal={Textiles}, publisher={MDPI AG}, author={Tuvshinbayar, Khorolsuren and Ehrmann, Guido and Ehrmann, Andrea}, year={2022}, pages={265–274} }","apa":"Tuvshinbayar, K., Ehrmann, G., &#38; Ehrmann, A. (2022). 50/60 Hz Power Grid Noise as a Skin Contact Measure of Textile ECG Electrodes. <i>Textiles</i>, <i>2</i>(2), 265–274. <a href=\"https://doi.org/10.3390/textiles2020014\">https://doi.org/10.3390/textiles2020014</a>","alphadin":"<span style=\"font-variant:small-caps;\">Tuvshinbayar, Khorolsuren</span> ; <span style=\"font-variant:small-caps;\">Ehrmann, Guido</span> ; <span style=\"font-variant:small-caps;\">Ehrmann, Andrea</span>: 50/60 Hz Power Grid Noise as a Skin Contact Measure of Textile ECG Electrodes. In: <i>Textiles</i> Bd. 2, MDPI AG (2022), Nr. 2, S. 265–274","ieee":"K. Tuvshinbayar, G. Ehrmann, and A. Ehrmann, “50/60 Hz Power Grid Noise as a Skin Contact Measure of Textile ECG Electrodes,” <i>Textiles</i>, vol. 2, no. 2, pp. 265–274, 2022."},"date_updated":"2026-03-17T15:28:27Z","publisher":"MDPI AG","user_id":"216459","file":[{"success":1,"date_updated":"2022-07-14T17:42:16Z","date_created":"2022-07-14T17:42:16Z","creator":"aehrmann","file_name":"_2022_Tuvshinbayar_Textiles2_265-274.pdf","file_size":4035374,"content_type":"application/pdf","relation":"main_file","file_id":"2024","access_level":"open_access"}],"type":"journal_article","publication_identifier":{"eissn":["2673-7248"]},"publication":"Textiles","department":[{"_id":"103"}],"quality_controlled":"1","volume":2,"date_created":"2022-07-14T17:42:43Z","title":"50/60 Hz Power Grid Noise as a Skin Contact Measure of Textile ECG Electrodes","file_date_updated":"2022-07-14T17:42:16Z","year":"2022","status":"public","page":"265-274","doi":"10.3390/textiles2020014","intvolume":"         2"}]
