[{"date_updated":"2026-03-17T15:28:42Z","page":"207-212","publisher":"Elsevier BV","doi":"10.1016/j.jss.2018.07.043","intvolume":"       233","status":"public","citation":{"chicago":"Schachtrupp, Alexander, Oliver Utz Wetter, and Jörg Höer. “Influence of Elevated Intra-Abdominal Pressure on Suture Tension Dynamics in a Porcine Model.” <i>Journal of Surgical Research</i> 233 (2019): 207–12. <a href=\"https://doi.org/10.1016/j.jss.2018.07.043\">https://doi.org/10.1016/j.jss.2018.07.043</a>.","short":"A. Schachtrupp, O.U. Wetter, J. Höer, Journal of Surgical Research 233 (2019) 207–212.","ama":"Schachtrupp A, Wetter OU, Höer J. Influence of Elevated Intra-abdominal Pressure on Suture Tension Dynamics in a Porcine Model. <i>Journal of Surgical Research</i>. 2019;233:207-212. doi:<a href=\"https://doi.org/10.1016/j.jss.2018.07.043\">10.1016/j.jss.2018.07.043</a>","mla":"Schachtrupp, Alexander, et al. “Influence of Elevated Intra-Abdominal Pressure on Suture Tension Dynamics in a Porcine Model.” <i>Journal of Surgical Research</i>, vol. 233, Elsevier BV, 2019, pp. 207–12, doi:<a href=\"https://doi.org/10.1016/j.jss.2018.07.043\">10.1016/j.jss.2018.07.043</a>.","ieee":"A. Schachtrupp, O. U. Wetter, and J. Höer, “Influence of Elevated Intra-abdominal Pressure on Suture Tension Dynamics in a Porcine Model,” <i>Journal of Surgical Research</i>, vol. 233, pp. 207–212, 2019.","apa":"Schachtrupp, A., Wetter, O. U., &#38; Höer, J. (2019). Influence of Elevated Intra-abdominal Pressure on Suture Tension Dynamics in a Porcine Model. <i>Journal of Surgical Research</i>, <i>233</i>, 207–212. <a href=\"https://doi.org/10.1016/j.jss.2018.07.043\">https://doi.org/10.1016/j.jss.2018.07.043</a>","bibtex":"@article{Schachtrupp_Wetter_Höer_2019, title={Influence of Elevated Intra-abdominal Pressure on Suture Tension Dynamics in a Porcine Model}, volume={233}, DOI={<a href=\"https://doi.org/10.1016/j.jss.2018.07.043\">10.1016/j.jss.2018.07.043</a>}, journal={Journal of Surgical Research}, publisher={Elsevier BV}, author={Schachtrupp, Alexander and Wetter, Oliver Utz and Höer, Jörg}, year={2019}, pages={207–212} }","alphadin":"<span style=\"font-variant:small-caps;\">Schachtrupp, Alexander</span> ; <span style=\"font-variant:small-caps;\">Wetter, Oliver Utz</span> ; <span style=\"font-variant:small-caps;\">Höer, Jörg</span>: Influence of Elevated Intra-abdominal Pressure on Suture Tension Dynamics in a Porcine Model. In: <i>Journal of Surgical Research</i> Bd. 233, Elsevier BV (2019), S. 207–212"},"author":[{"full_name":"Schachtrupp, Alexander","last_name":"Schachtrupp","first_name":"Alexander"},{"first_name":"Oliver Utz","id":"206920","orcid_put_code_url":"https://api.orcid.org/v2.0/0000-0003-3223-5050/work/203603694","orcid":"0000-0003-3223-5050","full_name":"Wetter, Oliver Utz","last_name":"Wetter"},{"first_name":"Jörg","last_name":"Höer","full_name":"Höer, Jörg"}],"language":[{"iso":"eng"}],"_id":"3229","year":"2019","volume":233,"date_created":"2023-06-15T13:02:39Z","title":"Influence of Elevated Intra-abdominal Pressure on Suture Tension Dynamics in a Porcine Model","department":[{"_id":"102"}],"quality_controlled":"1","keyword":["Intra-abdominal hypertension","Suture tension","Laparotomy closure","Incisional hernia","Ruptured abdomen","Implantable sensor"],"publication_status":"published","publication":"Journal of Surgical Research","user_id":"206920","project":[{"name":"Institute for Building Intelligence","_id":"A827C0AA-C7DA-11E9-B0AE-1F4CB252D58D"}],"publication_identifier":{"issn":["00224804"]},"type":"journal_article"},{"_id":"3230","year":"2018","language":[{"iso":"eng"}],"article_number":"1729","citation":{"short":"J. Höer, O.U. Wetter, Sensors 18 (2018).","chicago":"Höer, Jörg, and Oliver Utz Wetter. “Miniaturized Sensors Registering the Long-Term Course of Suture Tension In Vivo under Varying Intra-Abdominal Pressure.” <i>Sensors</i> 18, no. 6 (2018). <a href=\"https://doi.org/10.3390/s18061729\">https://doi.org/10.3390/s18061729</a>.","mla":"Höer, Jörg, and Oliver Utz Wetter. “Miniaturized Sensors Registering the Long-Term Course of Suture Tension In Vivo under Varying Intra-Abdominal Pressure.” <i>Sensors</i>, vol. 18, no. 6, 1729, MDPI AG, 2018, doi:<a href=\"https://doi.org/10.3390/s18061729\">10.3390/s18061729</a>.","ama":"Höer J, Wetter OU. Miniaturized Sensors Registering the Long-Term Course of Suture Tension In Vivo under Varying Intra-Abdominal Pressure. <i>Sensors</i>. 2018;18(6). doi:<a href=\"https://doi.org/10.3390/s18061729\">10.3390/s18061729</a>","ieee":"J. Höer and O. U. Wetter, “Miniaturized Sensors Registering the Long-Term Course of Suture Tension In Vivo under Varying Intra-Abdominal Pressure,” <i>Sensors</i>, vol. 18, no. 6, 2018.","alphadin":"<span style=\"font-variant:small-caps;\">Höer, Jörg</span> ; <span style=\"font-variant:small-caps;\">Wetter, Oliver Utz</span>: Miniaturized Sensors Registering the Long-Term Course of Suture Tension In Vivo under Varying Intra-Abdominal Pressure. In: <i>Sensors</i> Bd. 18, MDPI AG (2018), Nr. 6","bibtex":"@article{Höer_Wetter_2018, title={Miniaturized Sensors Registering the Long-Term Course of Suture Tension In Vivo under Varying Intra-Abdominal Pressure}, volume={18}, DOI={<a href=\"https://doi.org/10.3390/s18061729\">10.3390/s18061729</a>}, number={61729}, journal={Sensors}, publisher={MDPI AG}, author={Höer, Jörg and Wetter, Oliver Utz}, year={2018} }","apa":"Höer, J., &#38; Wetter, O. U. (2018). Miniaturized Sensors Registering the Long-Term Course of Suture Tension In Vivo under Varying Intra-Abdominal Pressure. <i>Sensors</i>, <i>18</i>(6). <a href=\"https://doi.org/10.3390/s18061729\">https://doi.org/10.3390/s18061729</a>"},"author":[{"full_name":"Höer, Jörg","last_name":"Höer","first_name":"Jörg"},{"id":"206920","orcid_put_code_url":"https://api.orcid.org/v2.0/0000-0003-3223-5050/work/203705976","first_name":"Oliver Utz","full_name":"Wetter, Oliver Utz","orcid":"0000-0003-3223-5050","last_name":"Wetter"}],"status":"public","doi":"10.3390/s18061729","intvolume":"        18","date_updated":"2026-03-17T15:28:42Z","publisher":"MDPI AG","oa":"1","tmp":{"short":"CC BY (4.0)","legal_code_url":"https://creativecommons.org/licenses/by/4.0/legalcode","name":"Creative Commons Attribution 4.0 International Public License (CC-BY 4.0)","image":"/images/cc_by.png"},"type":"journal_article","publication_identifier":{"eissn":["1424-8220"]},"main_file_link":[{"url":"https://www.mdpi.com/1424-8220/18/6/1729","open_access":"1"}],"user_id":"263827","keyword":["suture tension","incisional hernia","laparotomy closure","laparotomy","implantable sensor","tactile control","surgical complications","surgical technique"],"publication_status":"published","issue":"6","publication":"Sensors","quality_controlled":"1","date_created":"2023-06-15T13:09:14Z","title":"Miniaturized Sensors Registering the Long-Term Course of Suture Tension In Vivo under Varying Intra-Abdominal Pressure","volume":18}]