[{"status":"public","doi":"10.3390/coatings13091624","intvolume":"        13","year":"2023","article_number":"1624","funded_apc":"1","quality_controlled":"1","volume":13,"date_created":"2023-11-25T11:06:05Z","title":"Washing and Abrasion Resistance of Textile Electrodes for ECG Measurements","file_date_updated":"2023-11-25T11:05:37Z","user_id":"220548","publication_identifier":{"eissn":["2079-6412"]},"file":[{"access_level":"open_access","file_id":"3754","relation":"main_file","file_name":"_2023_Doci_Coatings13_1624.pdf","file_size":3807733,"content_type":"application/pdf","success":1,"date_updated":"2023-11-25T11:05:37Z","date_created":"2023-11-25T11:05:37Z","creator":"aehrmann"}],"type":"journal_article","publication":"Coatings","author":[{"first_name":"Dajana","full_name":"Doci, Dajana","last_name":"Doci"},{"first_name":"Melisa","full_name":"Ademi, Melisa","last_name":"Ademi"},{"id":"222971","first_name":"Khorolsuren","last_name":"Tuvshinbayar","full_name":"Tuvshinbayar, Khorolsuren","orcid":"0009-0001-7114-1842"},{"last_name":"Richter","full_name":"Richter, Niclas","orcid":"0000-0002-8980-0957","id":"224900","first_name":"Niclas"},{"full_name":"Ehrmann, Guido","last_name":"Ehrmann","first_name":"Guido"},{"last_name":"Spahiu","full_name":"Spahiu, Tatjana","first_name":"Tatjana"},{"full_name":"Ehrmann, Andrea","orcid":"0000-0003-0695-3905","last_name":"Ehrmann","id":"223776","first_name":"Andrea"}],"citation":{"short":"D. Doci, M. Ademi, K. Tuvshinbayar, N. Richter, G. Ehrmann, T. Spahiu, A. Ehrmann, Coatings 13 (2023).","chicago":"Doci, Dajana, Melisa Ademi, Khorolsuren Tuvshinbayar, Niclas Richter, Guido Ehrmann, Tatjana Spahiu, and Andrea Ehrmann. “Washing and Abrasion Resistance of Textile Electrodes for ECG Measurements.” <i>Coatings</i> 13, no. 9 (2023). <a href=\"https://doi.org/10.3390/coatings13091624\">https://doi.org/10.3390/coatings13091624</a>.","ama":"Doci D, Ademi M, Tuvshinbayar K, et al. Washing and Abrasion Resistance of Textile Electrodes for ECG Measurements. <i>Coatings</i>. 2023;13(9). doi:<a href=\"https://doi.org/10.3390/coatings13091624\">10.3390/coatings13091624</a>","mla":"Doci, Dajana, et al. “Washing and Abrasion Resistance of Textile Electrodes for ECG Measurements.” <i>Coatings</i>, vol. 13, no. 9, 1624, MDPI AG, 2023, doi:<a href=\"https://doi.org/10.3390/coatings13091624\">10.3390/coatings13091624</a>.","ieee":"D. Doci <i>et al.</i>, “Washing and Abrasion Resistance of Textile Electrodes for ECG Measurements,” <i>Coatings</i>, vol. 13, no. 9, 2023.","apa":"Doci, D., Ademi, M., Tuvshinbayar, K., Richter, N., Ehrmann, G., Spahiu, T., &#38; Ehrmann, A. (2023). Washing and Abrasion Resistance of Textile Electrodes for ECG Measurements. <i>Coatings</i>, <i>13</i>(9). <a href=\"https://doi.org/10.3390/coatings13091624\">https://doi.org/10.3390/coatings13091624</a>","bibtex":"@article{Doci_Ademi_Tuvshinbayar_Richter_Ehrmann_Spahiu_Ehrmann_2023, title={Washing and Abrasion Resistance of Textile Electrodes for ECG Measurements}, volume={13}, DOI={<a href=\"https://doi.org/10.3390/coatings13091624\">10.3390/coatings13091624</a>}, number={91624}, journal={Coatings}, publisher={MDPI AG}, author={Doci, Dajana and Ademi, Melisa and Tuvshinbayar, Khorolsuren and Richter, Niclas and Ehrmann, Guido and Spahiu, Tatjana and Ehrmann, Andrea}, year={2023} }","alphadin":"<span style=\"font-variant:small-caps;\">Doci, Dajana</span> ; <span style=\"font-variant:small-caps;\">Ademi, Melisa</span> ; <span style=\"font-variant:small-caps;\">Tuvshinbayar, Khorolsuren</span> ; <span style=\"font-variant:small-caps;\">Richter, Niclas</span> ; <span style=\"font-variant:small-caps;\">Ehrmann, Guido</span> ; <span style=\"font-variant:small-caps;\">Spahiu, Tatjana</span> ; <span style=\"font-variant:small-caps;\">Ehrmann, Andrea</span>: Washing and Abrasion Resistance of Textile Electrodes for ECG Measurements. In: <i>Coatings</i> Bd. 13, MDPI AG (2023), Nr. 9"},"date_updated":"2026-03-17T15:28:49Z","publisher":"MDPI AG","language":[{"iso":"eng"}],"_id":"3753","article_type":"original","main_file_link":[{"url":"https://www.mdpi.com/2079-6412/13/9/1624","open_access":"1"}],"has_accepted_license":"1","tmp":{"short":"CC BY (4.0)","legal_code_url":"https://creativecommons.org/licenses/by/4.0/legalcode","name":"Creative Commons Attribution 4.0 International Public License (CC-BY 4.0)","image":"/images/cc_by.png"},"oa":"1","urn":"urn:nbn:de:hbz:bi10-37530","keyword":["electrocardiogram (ECG)","textile electrodes","conductive coating","conductive yarn","sensor","Arduino"],"issue":"9","publication_status":"published"},{"article_number":"1521","language":[{"iso":"eng"}],"_id":"2767","year":"2023","date_updated":"2026-03-17T15:28:37Z","publisher":"MDPI AG","doi":"10.3390/electronics12071521","intvolume":"        12","status":"public","citation":{"chicago":"Richter, Niclas, Khorolsuren Tuvshinbayar, Guido Ehrmann, and Andrea Ehrmann. “Usability of Inexpensive Optical Pulse Sensors for Textile Integration and Heartbeat Detection Code Development.” <i>Electronics</i> 12, no. 7 (2023). <a href=\"https://doi.org/10.3390/electronics12071521\">https://doi.org/10.3390/electronics12071521</a>.","short":"N. Richter, K. Tuvshinbayar, G. Ehrmann, A. Ehrmann, Electronics 12 (2023).","mla":"Richter, Niclas, et al. “Usability of Inexpensive Optical Pulse Sensors for Textile Integration and Heartbeat Detection Code Development.” <i>Electronics</i>, vol. 12, no. 7, 1521, MDPI AG, 2023, doi:<a href=\"https://doi.org/10.3390/electronics12071521\">10.3390/electronics12071521</a>.","ama":"Richter N, Tuvshinbayar K, Ehrmann G, Ehrmann A. Usability of Inexpensive Optical Pulse Sensors for Textile Integration and Heartbeat Detection Code Development. <i>Electronics</i>. 2023;12(7). doi:<a href=\"https://doi.org/10.3390/electronics12071521\">10.3390/electronics12071521</a>","ieee":"N. Richter, K. Tuvshinbayar, G. Ehrmann, and A. Ehrmann, “Usability of Inexpensive Optical Pulse Sensors for Textile Integration and Heartbeat Detection Code Development,” <i>Electronics</i>, vol. 12, no. 7, 2023.","alphadin":"<span style=\"font-variant:small-caps;\">Richter, Niclas</span> ; <span style=\"font-variant:small-caps;\">Tuvshinbayar, Khorolsuren</span> ; <span style=\"font-variant:small-caps;\">Ehrmann, Guido</span> ; <span style=\"font-variant:small-caps;\">Ehrmann, Andrea</span>: Usability of Inexpensive Optical Pulse Sensors for Textile Integration and Heartbeat Detection Code Development. In: <i>Electronics</i> Bd. 12, MDPI AG (2023), Nr. 7","bibtex":"@article{Richter_Tuvshinbayar_Ehrmann_Ehrmann_2023, title={Usability of Inexpensive Optical Pulse Sensors for Textile Integration and Heartbeat Detection Code Development}, volume={12}, DOI={<a href=\"https://doi.org/10.3390/electronics12071521\">10.3390/electronics12071521</a>}, number={71521}, journal={Electronics}, publisher={MDPI AG}, author={Richter, Niclas and Tuvshinbayar, Khorolsuren and Ehrmann, Guido and Ehrmann, Andrea}, year={2023} }","apa":"Richter, N., Tuvshinbayar, K., Ehrmann, G., &#38; Ehrmann, A. (2023). Usability of Inexpensive Optical Pulse Sensors for Textile Integration and Heartbeat Detection Code Development. <i>Electronics</i>, <i>12</i>(7). <a href=\"https://doi.org/10.3390/electronics12071521\">https://doi.org/10.3390/electronics12071521</a>"},"author":[{"first_name":"Niclas","id":"224900","orcid_put_code_url":"https://api.orcid.org/v2.0/0000-0002-8980-0957/work/181737357","last_name":"Richter","orcid":"0000-0002-8980-0957","full_name":"Richter, Niclas"},{"full_name":"Tuvshinbayar, Khorolsuren","orcid":"0009-0001-7114-1842","last_name":"Tuvshinbayar","id":"222971","orcid_put_code_url":"https://api.orcid.org/v2.0/0009-0001-7114-1842/work/181737661","first_name":"Khorolsuren"},{"full_name":"Ehrmann, Guido","last_name":"Ehrmann","first_name":"Guido"},{"last_name":"Ehrmann","full_name":"Ehrmann, Andrea","orcid":"0000-0003-0695-3905","orcid_put_code_url":"https://api.orcid.org/v2.0/0000-0003-0695-3905/work/181737359","id":"223776","first_name":"Andrea"}],"urn":"urn:nbn:de:hbz:bi10-27676","keyword":["smart textiles","smart clothes","e-textiles","biosignal","vital signal","pulse sensor","microcontroller","washability","display"],"publication_status":"published","issue":"7","publication":"Electronics","user_id":"220548","oa":"1","tmp":{"short":"CC BY (4.0)","legal_code_url":"https://creativecommons.org/licenses/by/4.0/legalcode","name":"Creative Commons Attribution 4.0 International Public License (CC-BY 4.0)","image":"/images/cc_by.png"},"has_accepted_license":"1","file":[{"creator":"aehrmann","date_created":"2023-04-18T08:48:37Z","success":1,"date_updated":"2023-04-18T08:48:37Z","content_type":"application/pdf","file_name":"_2023_Richter_Electronics12_1521.pdf","file_size":4120222,"relation":"main_file","file_id":"2768","access_level":"open_access"}],"publication_identifier":{"eissn":["2079-9292"]},"type":"journal_article","volume":12,"date_created":"2023-04-18T08:49:13Z","article_type":"original","title":"Usability of Inexpensive Optical Pulse Sensors for Textile Integration and Heartbeat Detection Code Development","file_date_updated":"2023-04-18T08:48:37Z","quality_controlled":"1"},{"file":[{"relation":"main_file","file_id":"2024","access_level":"open_access","creator":"aehrmann","date_created":"2022-07-14T17:42:16Z","date_updated":"2022-07-14T17:42:16Z","success":1,"content_type":"application/pdf","file_name":"_2022_Tuvshinbayar_Textiles2_265-274.pdf","file_size":4035374}],"publication_identifier":{"eissn":["2673-7248"]},"type":"journal_article","user_id":"216459","publication":"Textiles","quality_controlled":"1","department":[{"_id":"103"}],"date_created":"2022-07-14T17:42:43Z","title":"50/60 Hz Power Grid Noise as a Skin Contact Measure of Textile ECG Electrodes","file_date_updated":"2022-07-14T17:42:16Z","volume":2,"year":"2022","status":"public","doi":"10.3390/textiles2020014","intvolume":"         2","page":"265-274","tmp":{"short":"CC BY (4.0)","legal_code_url":"https://creativecommons.org/licenses/by/4.0/legalcode","name":"Creative Commons Attribution 4.0 International Public License (CC-BY 4.0)","image":"/images/cc_by.png"},"oa":"1","has_accepted_license":"1","alternative_id":["2653","2647"],"main_file_link":[{"open_access":"1","url":"https://www.mdpi.com/2673-7248/2/2/14"}],"keyword":["electrocardiogram (ECG)","Arduino","electrodes","conductive coating","conductive yarn","sensor"],"urn":"urn:nbn:de:hbz:bi10-20230","issue":"2","publication_status":"published","article_type":"original","_id":"2023","language":[{"iso":"eng"}],"author":[{"first_name":"Khorolsuren","id":"222971","last_name":"Tuvshinbayar","orcid":"0009-0001-7114-1842","full_name":"Tuvshinbayar, Khorolsuren"},{"first_name":"Guido","full_name":"Ehrmann, Guido","last_name":"Ehrmann"},{"last_name":"Ehrmann","full_name":"Ehrmann, Andrea","orcid":"0000-0003-0695-3905","id":"223776","first_name":"Andrea"}],"citation":{"chicago":"Tuvshinbayar, Khorolsuren, Guido Ehrmann, and Andrea Ehrmann. “50/60 Hz Power Grid Noise as a Skin Contact Measure of Textile ECG Electrodes.” <i>Textiles</i> 2, no. 2 (2022): 265–74. <a href=\"https://doi.org/10.3390/textiles2020014\">https://doi.org/10.3390/textiles2020014</a>.","short":"K. Tuvshinbayar, G. Ehrmann, A. Ehrmann, Textiles 2 (2022) 265–274.","ama":"Tuvshinbayar K, Ehrmann G, Ehrmann A. 50/60 Hz Power Grid Noise as a Skin Contact Measure of Textile ECG Electrodes. <i>Textiles</i>. 2022;2(2):265-274. doi:<a href=\"https://doi.org/10.3390/textiles2020014\">10.3390/textiles2020014</a>","mla":"Tuvshinbayar, Khorolsuren, et al. “50/60 Hz Power Grid Noise as a Skin Contact Measure of Textile ECG Electrodes.” <i>Textiles</i>, vol. 2, no. 2, MDPI AG, 2022, pp. 265–74, doi:<a href=\"https://doi.org/10.3390/textiles2020014\">10.3390/textiles2020014</a>.","ieee":"K. Tuvshinbayar, G. Ehrmann, and A. Ehrmann, “50/60 Hz Power Grid Noise as a Skin Contact Measure of Textile ECG Electrodes,” <i>Textiles</i>, vol. 2, no. 2, pp. 265–274, 2022.","apa":"Tuvshinbayar, K., Ehrmann, G., &#38; Ehrmann, A. (2022). 50/60 Hz Power Grid Noise as a Skin Contact Measure of Textile ECG Electrodes. <i>Textiles</i>, <i>2</i>(2), 265–274. <a href=\"https://doi.org/10.3390/textiles2020014\">https://doi.org/10.3390/textiles2020014</a>","bibtex":"@article{Tuvshinbayar_Ehrmann_Ehrmann_2022, title={50/60 Hz Power Grid Noise as a Skin Contact Measure of Textile ECG Electrodes}, volume={2}, DOI={<a href=\"https://doi.org/10.3390/textiles2020014\">10.3390/textiles2020014</a>}, number={2}, journal={Textiles}, publisher={MDPI AG}, author={Tuvshinbayar, Khorolsuren and Ehrmann, Guido and Ehrmann, Andrea}, year={2022}, pages={265–274} }","alphadin":"<span style=\"font-variant:small-caps;\">Tuvshinbayar, Khorolsuren</span> ; <span style=\"font-variant:small-caps;\">Ehrmann, Guido</span> ; <span style=\"font-variant:small-caps;\">Ehrmann, Andrea</span>: 50/60 Hz Power Grid Noise as a Skin Contact Measure of Textile ECG Electrodes. In: <i>Textiles</i> Bd. 2, MDPI AG (2022), Nr. 2, S. 265–274"},"date_updated":"2026-03-17T15:28:27Z","publisher":"MDPI AG"},{"date_updated":"2026-03-17T15:28:42Z","page":"207-212","publisher":"Elsevier BV","doi":"10.1016/j.jss.2018.07.043","intvolume":"       233","status":"public","author":[{"full_name":"Schachtrupp, Alexander","last_name":"Schachtrupp","first_name":"Alexander"},{"first_name":"Oliver Utz","orcid_put_code_url":"https://api.orcid.org/v2.0/0000-0003-3223-5050/work/203603694","id":"206920","last_name":"Wetter","orcid":"0000-0003-3223-5050","full_name":"Wetter, Oliver Utz"},{"first_name":"Jörg","full_name":"Höer, Jörg","last_name":"Höer"}],"citation":{"ieee":"A. Schachtrupp, O. U. Wetter, and J. Höer, “Influence of Elevated Intra-abdominal Pressure on Suture Tension Dynamics in a Porcine Model,” <i>Journal of Surgical Research</i>, vol. 233, pp. 207–212, 2019.","bibtex":"@article{Schachtrupp_Wetter_Höer_2019, title={Influence of Elevated Intra-abdominal Pressure on Suture Tension Dynamics in a Porcine Model}, volume={233}, DOI={<a href=\"https://doi.org/10.1016/j.jss.2018.07.043\">10.1016/j.jss.2018.07.043</a>}, journal={Journal of Surgical Research}, publisher={Elsevier BV}, author={Schachtrupp, Alexander and Wetter, Oliver Utz and Höer, Jörg}, year={2019}, pages={207–212} }","apa":"Schachtrupp, A., Wetter, O. U., &#38; Höer, J. (2019). Influence of Elevated Intra-abdominal Pressure on Suture Tension Dynamics in a Porcine Model. <i>Journal of Surgical Research</i>, <i>233</i>, 207–212. <a href=\"https://doi.org/10.1016/j.jss.2018.07.043\">https://doi.org/10.1016/j.jss.2018.07.043</a>","alphadin":"<span style=\"font-variant:small-caps;\">Schachtrupp, Alexander</span> ; <span style=\"font-variant:small-caps;\">Wetter, Oliver Utz</span> ; <span style=\"font-variant:small-caps;\">Höer, Jörg</span>: Influence of Elevated Intra-abdominal Pressure on Suture Tension Dynamics in a Porcine Model. In: <i>Journal of Surgical Research</i> Bd. 233, Elsevier BV (2019), S. 207–212","short":"A. Schachtrupp, O.U. Wetter, J. Höer, Journal of Surgical Research 233 (2019) 207–212.","chicago":"Schachtrupp, Alexander, Oliver Utz Wetter, and Jörg Höer. “Influence of Elevated Intra-Abdominal Pressure on Suture Tension Dynamics in a Porcine Model.” <i>Journal of Surgical Research</i> 233 (2019): 207–12. <a href=\"https://doi.org/10.1016/j.jss.2018.07.043\">https://doi.org/10.1016/j.jss.2018.07.043</a>.","ama":"Schachtrupp A, Wetter OU, Höer J. Influence of Elevated Intra-abdominal Pressure on Suture Tension Dynamics in a Porcine Model. <i>Journal of Surgical Research</i>. 2019;233:207-212. doi:<a href=\"https://doi.org/10.1016/j.jss.2018.07.043\">10.1016/j.jss.2018.07.043</a>","mla":"Schachtrupp, Alexander, et al. “Influence of Elevated Intra-Abdominal Pressure on Suture Tension Dynamics in a Porcine Model.” <i>Journal of Surgical Research</i>, vol. 233, Elsevier BV, 2019, pp. 207–12, doi:<a href=\"https://doi.org/10.1016/j.jss.2018.07.043\">10.1016/j.jss.2018.07.043</a>."},"language":[{"iso":"eng"}],"_id":"3229","year":"2019","volume":233,"date_created":"2023-06-15T13:02:39Z","title":"Influence of Elevated Intra-abdominal Pressure on Suture Tension Dynamics in a Porcine Model","department":[{"_id":"102"}],"quality_controlled":"1","keyword":["Intra-abdominal hypertension","Suture tension","Laparotomy closure","Incisional hernia","Ruptured abdomen","Implantable sensor"],"publication_status":"published","publication":"Journal of Surgical Research","user_id":"206920","project":[{"_id":"A827C0AA-C7DA-11E9-B0AE-1F4CB252D58D","name":"Institute for Building Intelligence"}],"publication_identifier":{"issn":["00224804"]},"type":"journal_article"},{"title":"Miniaturized Sensors Registering the Long-Term Course of Suture Tension In Vivo under Varying Intra-Abdominal Pressure","date_created":"2023-06-15T13:09:14Z","volume":18,"quality_controlled":"1","issue":"6","publication":"Sensors","publication_status":"published","keyword":["suture tension","incisional hernia","laparotomy closure","laparotomy","implantable sensor","tactile control","surgical complications","surgical technique"],"type":"journal_article","publication_identifier":{"eissn":["1424-8220"]},"oa":"1","tmp":{"short":"CC BY (4.0)","legal_code_url":"https://creativecommons.org/licenses/by/4.0/legalcode","name":"Creative Commons Attribution 4.0 International Public License (CC-BY 4.0)","image":"/images/cc_by.png"},"user_id":"263827","main_file_link":[{"url":"https://www.mdpi.com/1424-8220/18/6/1729","open_access":"1"}],"intvolume":"        18","doi":"10.3390/s18061729","publisher":"MDPI AG","date_updated":"2026-03-17T15:28:42Z","citation":{"bibtex":"@article{Höer_Wetter_2018, title={Miniaturized Sensors Registering the Long-Term Course of Suture Tension In Vivo under Varying Intra-Abdominal Pressure}, volume={18}, DOI={<a href=\"https://doi.org/10.3390/s18061729\">10.3390/s18061729</a>}, number={61729}, journal={Sensors}, publisher={MDPI AG}, author={Höer, Jörg and Wetter, Oliver Utz}, year={2018} }","apa":"Höer, J., &#38; Wetter, O. U. (2018). Miniaturized Sensors Registering the Long-Term Course of Suture Tension In Vivo under Varying Intra-Abdominal Pressure. <i>Sensors</i>, <i>18</i>(6). <a href=\"https://doi.org/10.3390/s18061729\">https://doi.org/10.3390/s18061729</a>","alphadin":"<span style=\"font-variant:small-caps;\">Höer, Jörg</span> ; <span style=\"font-variant:small-caps;\">Wetter, Oliver Utz</span>: Miniaturized Sensors Registering the Long-Term Course of Suture Tension In Vivo under Varying Intra-Abdominal Pressure. In: <i>Sensors</i> Bd. 18, MDPI AG (2018), Nr. 6","ieee":"J. Höer and O. U. Wetter, “Miniaturized Sensors Registering the Long-Term Course of Suture Tension In Vivo under Varying Intra-Abdominal Pressure,” <i>Sensors</i>, vol. 18, no. 6, 2018.","ama":"Höer J, Wetter OU. Miniaturized Sensors Registering the Long-Term Course of Suture Tension In Vivo under Varying Intra-Abdominal Pressure. <i>Sensors</i>. 2018;18(6). doi:<a href=\"https://doi.org/10.3390/s18061729\">10.3390/s18061729</a>","mla":"Höer, Jörg, and Oliver Utz Wetter. “Miniaturized Sensors Registering the Long-Term Course of Suture Tension In Vivo under Varying Intra-Abdominal Pressure.” <i>Sensors</i>, vol. 18, no. 6, 1729, MDPI AG, 2018, doi:<a href=\"https://doi.org/10.3390/s18061729\">10.3390/s18061729</a>.","short":"J. Höer, O.U. Wetter, Sensors 18 (2018).","chicago":"Höer, Jörg, and Oliver Utz Wetter. “Miniaturized Sensors Registering the Long-Term Course of Suture Tension In Vivo under Varying Intra-Abdominal Pressure.” <i>Sensors</i> 18, no. 6 (2018). <a href=\"https://doi.org/10.3390/s18061729\">https://doi.org/10.3390/s18061729</a>."},"author":[{"last_name":"Höer","full_name":"Höer, Jörg","first_name":"Jörg"},{"first_name":"Oliver Utz","orcid_put_code_url":"https://api.orcid.org/v2.0/0000-0003-3223-5050/work/203705976","id":"206920","last_name":"Wetter","orcid":"0000-0003-3223-5050","full_name":"Wetter, Oliver Utz"}],"status":"public","article_number":"1729","year":"2018","_id":"3230","language":[{"iso":"eng"}]},{"quality_controlled":"1","title":"Modeling of Nanoparticular Magnetoresistive Systems and the Impact on Molecular Recognition","date_created":"2021-07-06T09:07:33Z","volume":15,"type":"journal_article","publication_identifier":{"eissn":["1424-8220"]},"tmp":{"short":"CC BY (4.0)","legal_code_url":"https://creativecommons.org/licenses/by/4.0/legalcode","name":"Creative Commons Attribution 4.0 International Public License (CC-BY 4.0)","image":"/images/cc_by.png"},"project":[{"_id":"f89a05bb-bcea-11ed-9442-ed382659bc06","name":"Bielefelder Institut für Angewandte Materialforschung"}],"user_id":"35809","publication":"Sensors","issue":"4","publication_status":"published","keyword":["hybrid combination of classical spin dynamics and molecular dynamics simulations","nanoparticular GMR-effect","sensor based determination of association and dissociation constants in molecular recognition"],"author":[{"first_name":"Lisa","last_name":"Teich","full_name":"Teich, Lisa"},{"last_name":"Kappe","full_name":"Kappe, Daniel","first_name":"Daniel"},{"last_name":"Rempel","full_name":"Rempel, Thomas","first_name":"Thomas"},{"last_name":"Meyer","full_name":"Meyer, Judith","first_name":"Judith"},{"last_name":"Schröder","orcid":"0000-0002-6391-6548","full_name":"Schröder, Christian","first_name":"Christian","id":"35809","orcid_put_code_url":"https://api.orcid.org/v2.0/0000-0002-6391-6548/work/96660577"},{"full_name":"Hütten, Andreas","last_name":"Hütten","first_name":"Andreas"}],"citation":{"apa":"Teich, L., Kappe, D., Rempel, T., Meyer, J., Schröder, C., &#38; Hütten, A. (2015). Modeling of Nanoparticular Magnetoresistive Systems and the Impact on Molecular Recognition. <i>Sensors</i>, <i>15</i>(4), 9251–9264. <a href=\"https://doi.org/10.3390/s150409251\">https://doi.org/10.3390/s150409251</a>","bibtex":"@article{Teich_Kappe_Rempel_Meyer_Schröder_Hütten_2015, title={Modeling of Nanoparticular Magnetoresistive Systems and the Impact on Molecular Recognition}, volume={15}, DOI={<a href=\"https://doi.org/10.3390/s150409251\">10.3390/s150409251</a>}, number={4}, journal={Sensors}, publisher={MDPI AG}, author={Teich, Lisa and Kappe, Daniel and Rempel, Thomas and Meyer, Judith and Schröder, Christian and Hütten, Andreas}, year={2015}, pages={9251–9264} }","alphadin":"<span style=\"font-variant:small-caps;\">Teich, Lisa</span> ; <span style=\"font-variant:small-caps;\">Kappe, Daniel</span> ; <span style=\"font-variant:small-caps;\">Rempel, Thomas</span> ; <span style=\"font-variant:small-caps;\">Meyer, Judith</span> ; <span style=\"font-variant:small-caps;\">Schröder, Christian</span> ; <span style=\"font-variant:small-caps;\">Hütten, Andreas</span>: Modeling of Nanoparticular Magnetoresistive Systems and the Impact on Molecular Recognition. In: <i>Sensors</i> Bd. 15, MDPI AG (2015), Nr. 4, S. 9251–9264","ieee":"L. Teich, D. Kappe, T. Rempel, J. Meyer, C. Schröder, and A. Hütten, “Modeling of Nanoparticular Magnetoresistive Systems and the Impact on Molecular Recognition,” <i>Sensors</i>, vol. 15, no. 4, pp. 9251–9264, 2015.","ama":"Teich L, Kappe D, Rempel T, Meyer J, Schröder C, Hütten A. Modeling of Nanoparticular Magnetoresistive Systems and the Impact on Molecular Recognition. <i>Sensors</i>. 2015;15(4):9251-9264. doi:<a href=\"https://doi.org/10.3390/s150409251\">10.3390/s150409251</a>","mla":"Teich, Lisa, et al. “Modeling of Nanoparticular Magnetoresistive Systems and the Impact on Molecular Recognition.” <i>Sensors</i>, vol. 15, no. 4, MDPI AG, 2015, pp. 9251–64, doi:<a href=\"https://doi.org/10.3390/s150409251\">10.3390/s150409251</a>.","chicago":"Teich, Lisa, Daniel Kappe, Thomas Rempel, Judith Meyer, Christian Schröder, and Andreas Hütten. “Modeling of Nanoparticular Magnetoresistive Systems and the Impact on Molecular Recognition.” <i>Sensors</i> 15, no. 4 (2015): 9251–64. <a href=\"https://doi.org/10.3390/s150409251\">https://doi.org/10.3390/s150409251</a>.","short":"L. Teich, D. Kappe, T. Rempel, J. Meyer, C. Schröder, A. Hütten, Sensors 15 (2015) 9251–9264."},"status":"public","intvolume":"        15","doi":"10.3390/s150409251","page":"9251-9264","publisher":"MDPI AG","date_updated":"2026-03-17T15:28:20Z","year":"2015","_id":"1437","language":[{"iso":"eng"}]},{"volume":84,"date_created":"2019-05-28T06:59:58Z","title":"Conceptual design of a sensory shirt for fire-fighters","main_file_link":[{"open_access":"1"}],"user_id":"35437","oa":"1","publication_identifier":{"eissn":["1746-7748"],"unknown":["0040-5175"]},"type":"journal_article","keyword":["Sensory shirt","fire-fighters","ECG","skin temperature","breathing sensor","pattern construction","conductive paths"],"issue":"15","publication":"Textile Research Journal","status":"public","author":[{"full_name":"Aumann, S.","last_name":"Aumann","first_name":"S."},{"full_name":"Trummer, S.","last_name":"Trummer","first_name":"S."},{"last_name":"Brucken","full_name":"Brucken, A.","first_name":"A."},{"full_name":"Ehrmann, Andrea","orcid":"0000-0003-0695-3905","last_name":"Ehrmann","id":"223776","orcid_put_code_url":"https://api.orcid.org/v2.0/0000-0003-0695-3905/work/177373768","first_name":"Andrea"},{"first_name":"A.","full_name":"Busgen, A.","last_name":"Busgen"}],"citation":{"bibtex":"@article{Aumann_Trummer_Brucken_Ehrmann_Busgen_2014, title={Conceptual design of a sensory shirt for fire-fighters}, volume={84}, DOI={<a href=\"https://doi.org/10.1177/0040517514525882\">https://doi.org/10.1177/0040517514525882</a>}, number={15}, journal={Textile Research Journal}, author={Aumann, S. and Trummer, S. and Brucken, A. and Ehrmann, Andrea and Busgen, A.}, year={2014}, pages={1661–1665} }","apa":"Aumann, S., Trummer, S., Brucken, A., Ehrmann, A., &#38; Busgen, A. (2014). Conceptual design of a sensory shirt for fire-fighters. <i>Textile Research Journal</i>, <i>84</i>(15), 1661–1665. <a href=\"https://doi.org/10.1177/0040517514525882\">https://doi.org/10.1177/0040517514525882</a>","alphadin":"<span style=\"font-variant:small-caps;\">Aumann, S.</span> ; <span style=\"font-variant:small-caps;\">Trummer, S.</span> ; <span style=\"font-variant:small-caps;\">Brucken, A.</span> ; <span style=\"font-variant:small-caps;\">Ehrmann, Andrea</span> ; <span style=\"font-variant:small-caps;\">Busgen, A.</span>: Conceptual design of a sensory shirt for fire-fighters. In: <i>Textile Research Journal</i> Bd. 84 (2014), Nr. 15, S. 1661–1665","ieee":"S. Aumann, S. Trummer, A. Brucken, A. Ehrmann, and A. Busgen, “Conceptual design of a sensory shirt for fire-fighters,” <i>Textile Research Journal</i>, vol. 84, no. 15, pp. 1661–1665, 2014.","ama":"Aumann S, Trummer S, Brucken A, Ehrmann A, Busgen A. Conceptual design of a sensory shirt for fire-fighters. <i>Textile Research Journal</i>. 2014;84(15):1661-1665. doi:<a href=\"https://doi.org/10.1177/0040517514525882\">https://doi.org/10.1177/0040517514525882</a>","mla":"Aumann, S., et al. “Conceptual Design of a Sensory Shirt for Fire-Fighters.” <i>Textile Research Journal</i>, vol. 84, no. 15, 2014, pp. 1661–65, doi:<a href=\"https://doi.org/10.1177/0040517514525882\">https://doi.org/10.1177/0040517514525882</a>.","chicago":"Aumann, S., S. Trummer, A. Brucken, Andrea Ehrmann, and A. Busgen. “Conceptual Design of a Sensory Shirt for Fire-Fighters.” <i>Textile Research Journal</i> 84, no. 15 (2014): 1661–65. <a href=\"https://doi.org/10.1177/0040517514525882\">https://doi.org/10.1177/0040517514525882</a>.","short":"S. Aumann, S. Trummer, A. Brucken, A. Ehrmann, A. Busgen, Textile Research Journal 84 (2014) 1661–1665."},"date_updated":"2026-03-17T15:28:51Z","page":"1661-1665","doi":"https://doi.org/10.1177/0040517514525882","intvolume":"        84","language":[{"iso":"eng"}],"_id":"387","year":"2014"},{"status":"public","author":[{"orcid":"0000-0003-0695-3905","full_name":"Ehrmann, Andrea","last_name":"Ehrmann","first_name":"Andrea","orcid_put_code_url":"https://api.orcid.org/v2.0/0000-0003-0695-3905/work/177216653","id":"223776"},{"full_name":"Heimlich, F.","last_name":"Heimlich","first_name":"F."},{"first_name":"A.","full_name":"Brucken, A.","last_name":"Brucken"},{"last_name":"Weber","full_name":"Weber, M. O.","first_name":"M. O."},{"first_name":"R.","last_name":"Haug","full_name":"Haug, R."}],"citation":{"ieee":"A. Ehrmann, F. Heimlich, A. Brucken, M. O. Weber, and R. Haug, “Suitability of knitted fabrics as elongation sensors subject to structure, stitch dimension and elongation direction,” <i>Textile Research Journal</i>, vol. 84, no. 18, pp. 2006–2012, 2014.","bibtex":"@article{Ehrmann_Heimlich_Brucken_Weber_Haug_2014, title={Suitability of knitted fabrics as elongation sensors subject to structure, stitch dimension and elongation direction}, volume={84}, DOI={<a href=\"https://doi.org/10.1177/0040517514548812\">10.1177/0040517514548812</a>}, number={18}, journal={Textile Research Journal}, author={Ehrmann, Andrea and Heimlich, F. and Brucken, A. and Weber, M. O. and Haug, R.}, year={2014}, pages={2006–2012} }","apa":"Ehrmann, A., Heimlich, F., Brucken, A., Weber, M. O., &#38; Haug, R. (2014). Suitability of knitted fabrics as elongation sensors subject to structure, stitch dimension and elongation direction. <i>Textile Research Journal</i>, <i>84</i>(18), 2006–2012. <a href=\"https://doi.org/10.1177/0040517514548812\">https://doi.org/10.1177/0040517514548812</a>","alphadin":"<span style=\"font-variant:small-caps;\">Ehrmann, Andrea</span> ; <span style=\"font-variant:small-caps;\">Heimlich, F.</span> ; <span style=\"font-variant:small-caps;\">Brucken, A.</span> ; <span style=\"font-variant:small-caps;\">Weber, M. O.</span> ; <span style=\"font-variant:small-caps;\">Haug, R.</span>: Suitability of knitted fabrics as elongation sensors subject to structure, stitch dimension and elongation direction. In: <i>Textile Research Journal</i> Bd. 84 (2014), Nr. 18, S. 2006–2012","short":"A. Ehrmann, F. Heimlich, A. Brucken, M.O. Weber, R. Haug, Textile Research Journal 84 (2014) 2006–2012.","chicago":"Ehrmann, Andrea, F. Heimlich, A. Brucken, M. O. Weber, and R. Haug. “Suitability of Knitted Fabrics as Elongation Sensors Subject to Structure, Stitch Dimension and Elongation Direction.” <i>Textile Research Journal</i> 84, no. 18 (2014): 2006–12. <a href=\"https://doi.org/10.1177/0040517514548812\">https://doi.org/10.1177/0040517514548812</a>.","ama":"Ehrmann A, Heimlich F, Brucken A, Weber MO, Haug R. Suitability of knitted fabrics as elongation sensors subject to structure, stitch dimension and elongation direction. <i>Textile Research Journal</i>. 2014;84(18):2006-2012. doi:<a href=\"https://doi.org/10.1177/0040517514548812\">10.1177/0040517514548812</a>","mla":"Ehrmann, Andrea, et al. “Suitability of Knitted Fabrics as Elongation Sensors Subject to Structure, Stitch Dimension and Elongation Direction.” <i>Textile Research Journal</i>, vol. 84, no. 18, 2014, pp. 2006–12, doi:<a href=\"https://doi.org/10.1177/0040517514548812\">10.1177/0040517514548812</a>."},"date_updated":"2026-03-17T15:28:50Z","page":"2006-2012","doi":"10.1177/0040517514548812","intvolume":"        84","language":[{"iso":"eng"}],"_id":"385","year":"2014","volume":84,"date_created":"2019-05-28T06:59:58Z","title":"Suitability of knitted fabrics as elongation sensors subject to structure, stitch dimension and elongation direction","main_file_link":[{"open_access":"1","url":"https://journals.sagepub.com/doi/10.1177/0040517514548812"}],"user_id":"33980","oa":"1","publication_identifier":{"issn":["0040-5175"],"eissn":["1746-7748"]},"type":"journal_article","keyword":["elongation sensor","conductive fabric","knitted fabric","stainless steel fiber yarn","cotton yarn","elongation direction"],"publication":"Textile Research Journal","issue":"18"}]
